A. | Occupancy Classification |
|
|
|
| (CBC Ch. 3 and CBC Table 1004.1.1, Table 1015.1 & Table 1019.1) |
|
|
|
|
|
|
|
| 1 | Occupancy Type: | R2, M, U | | |
|
| (CBC Ch. 3; for mixed occupancy, see CBC Sec 302) |
|
|
|
|
|
|
|
| separate or | Accessory Occupancy: | x-x | | |
| accessory? | (CBC Sec 504.3.2) |
|
|
|
|
|
|
|
|
|
| 2 | Building Floor Area: | 14,000 | | |
|
| Group R-2: | 7000 |
|
|
|
| Group M: | 1000 |
|
|
|
| Group U: | 6000 |
|
|
|
| (CBC Sec. 506.3) |
|
|
|
| 3 | Occupant Load: | 71 | | |
|
| (CBC Table 1004.1.1) |
|
|
|
|
|
|
|
|
|
| 4 | Occupancy Separation: | |
|
| (CBC Table 508.3.3) | for buildings equiped throughout w/an automatic sprinkler system |
|
|
| installed in accordance with section 903.3.1.1 |
|
|
|
|
|
|
|
| 5 | Spaces with One Means of Egress: |
|
|
|
| Group R-2: | 10 max occupant load | 1 |
|
|
| Group M: | 49 max occupant load | 1 |
|
|
| Group U: | 49 max occupant load | 1 |
|
|
| (CBC Table 1015.1) |
|
|
|
|
|
|
|
|
|
| 6 | Exit Access Travel Distance: |
|
|
|
| Group R-2: | 250 FT w/sprinkler system | 200 |
|
|
| Group M: | 250 FT w/sprinkler system | 200 |
|
|
| Group U: | 400 FT w/sprinkler system | 300 |
|
|
| (CBC Table 1016.1) |
|
|
|
|
|
|
|
|
|
| 7 | Minimum No. of Exits per Occupant Load: |
|
|
|
| 1-500 | 2 per story |
|
|
|
| 501-1,000 | 3 per story |
|
|
|
| (CBC Table 1019.1) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
D. | Allowable Floor Area |
|
|
|
| (CBC Ch. 5 and Table 5-B) |
|
|
|
|
|
|
|
|
|
| Based on Construction Type IIA |
|
|
|
| Group R-2: |
|
|
|
| 1 | Basic Allowable Height: | 65' / 4 Stories | | |
|
| (Bldg height / # of stories) |
|
|
|
|
|
|
|
|
| 2 | Basic Allowable Flr Area: | 24000 SF | | |
|
| (CBC Table 503) |
|
|
|
|
|
|
|
|
|
| 3 | Yard Separation Increase: | 6400 SF | | |
|
| (CBC Sec 505.1) |
|
|
|
|
|
|
|
|
|
| 4 | Multi-story Increase: | 24000 SF |
|
|
|
| (CBC Sec 504.2) |
|
|
|
|
|
|
|
|
|
| Group M: |
|
|
|
|
| 1 | Basic Allowable Height: | 65' / 4 Stories | | |
|
| (Bldg height / # of stories) |
|
|
|
|
|
|
|
|
| 2 | Basic Allowable Flr Area: | 21,500 SF | | |
|
| (CBC Table 503) |
|
|
|
|
|
|
|
|
|
| 3 | Yard Separation Increase: | 3,733 SF | | |
|
| (CBC Sec 505.1) |
|
|
|
|
|
|
|
|
|
| 4 | Multi-story Increase: | 21500 SF |
|
|
|
| (CBC Sec 504.2) |
|
|
|
|
|
|
|
|
|
| Group U: |
|
|
|
|
| 1 | Basic Allowable Height: | 65' / 5 Stories | | |
|
| (Bldg height / # of stories) |
|
|
|
|
|
|
|
|
| 2 | Basic Allowable Flr Area: | 35500 SF | | |
|
| (CBC Table 503) |
|
|
|
|
|
|
|
|
|
| 3 | Yard Separation Increase: | 0 | | |
|
| (CBC Sec 505.1) | 0 |
|
|
|
|
|
|
|
|
| 4 | Multi-story Increase: | 0 |
|
|
|
| (CBC Sec 504.2) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
E. | Actual Floor Area: |
|
|
|
|
|
|
|
|
|
| Occupancy Type: | R-2 |
|
|
|
|
|
|
|
|
|
| Floor Level: | ASF | | |
|
| Basement | 0 | < 54,400 SF | |
|
| First Floor | 0 | < 54,400 SF | |
|
| Second Floor | 3,350 | < 54,400 SF | |
|
| Third Floor | 4460 | < 54,400 SF | |
|
| Fourth Floor | 1815 | < 54,400 SF | |
|
| Total Actual Floor Area | 9,625 | | |
|
|
|
|
|
|
|
|
|
|
|
|
| Occupancy Type: | M |
|
|
|
|
|
|
|
|
|
| Floor Level: | ASF | | |
|
| Basement | 0 | < 46,733 SF | |
|
| First Floor | 0 | < 46,733 SF | |
|
| Second Floor | 1000 | < 46,733 SF | |
|
| Third Floor | 0 | < 46,733 SF | |
|
| Fourth Floor | 0 | < 46,733 SF | |
|
| Total Actual Floor Area | 1000 | | |
|
|
|
|
|
|
| Occupancy Type: | U |
|
|
|
|
|
|
|
|
|
| Floor Level: | ASF | | |
|
| Basement | 0 | < 35,500 SF | |
|
| First Floor | 6000 | < 35,500 SF | |
|
| Second Floor | 0 | < 35,500 SF | |
|
| Third Floor | 0 | < 35,500 SF | |
|
| Fourth Floor | 0 | < 35,500 SF | |
|
| Total Actual Floor Area | 6000 | | |