Code Analysis
A. | Occupancy Classification | ||||
(CBC Ch. 3 and CBC Table 1004.1.1, Table 1015.1 & Table 1019.1) | |||||
1 | Occupancy Type: | R2, M, U | |||
(CBC Ch. 3; for mixed occupancy, see CBC Sec 302) | |||||
separate or | Accessory Occupancy: | x-x | |||
accessory? | (CBC Sec 504.3.2) | ||||
2 | Building Floor Area: | 14,000 | |||
Group R-2: | 7000 | ||||
Group M: | 1000 | ||||
Group U: | 6000 | ||||
(CBC Sec. 506.3) | |||||
3 | Occupant Load: | 71 | |||
(CBC Table 1004.1.1) | |||||
4 | Occupancy Separation: | ||||
(CBC Table 508.3.3) | for buildings equiped throughout w/an automatic sprinkler system | ||||
installed in accordance with section 903.3.1.1 | |||||
5 | Spaces with One Means of Egress: | ||||
Group R-2: | 10 max occupant load | 1 | |||
Group M: | 49 max occupant load | 1 | |||
Group U: | 49 max occupant load | 1 | |||
(CBC Table 1015.1) | |||||
6 | Exit Access Travel Distance: | ||||
Group R-2: | 250 FT w/sprinkler system | 200 | |||
Group M: | 250 FT w/sprinkler system | 200 | |||
Group U: | 400 FT w/sprinkler system | 300 | |||
(CBC Table 1016.1) | |||||
7 | Minimum No. of Exits per Occupant Load: | ||||
1-500 | 2 per story | ||||
501-1,000 | 3 per story | ||||
(CBC Table 1019.1) | |||||
D. | Allowable Floor Area | ||||
(CBC Ch. 5 and Table 5-B) | |||||
Based on Construction Type IIA | |||||
Group R-2: | |||||
1 | Basic Allowable Height: | 65' / 4 Stories | |||
(Bldg height / # of stories) | |||||
2 | Basic Allowable Flr Area: | 24000 SF | |||
(CBC Table 503) | |||||
3 | Yard Separation Increase: | 6400 SF | |||
(CBC Sec 505.1) | |||||
4 | Multi-story Increase: | 24000 SF | |||
(CBC Sec 504.2) | |||||
Group M: | |||||
1 | Basic Allowable Height: | 65' / 4 Stories | |||
(Bldg height / # of stories) | |||||
2 | Basic Allowable Flr Area: | 21,500 SF | |||
(CBC Table 503) | |||||
3 | Yard Separation Increase: | 3,733 SF | |||
(CBC Sec 505.1) | |||||
4 | Multi-story Increase: | 21500 SF | |||
(CBC Sec 504.2) | |||||
Group U: | |||||
1 | Basic Allowable Height: | 65' / 5 Stories | |||
(Bldg height / # of stories) | |||||
2 | Basic Allowable Flr Area: | 35500 SF | |||
(CBC Table 503) | |||||
3 | Yard Separation Increase: | 0 | |||
(CBC Sec 505.1) | 0 | ||||
4 | Multi-story Increase: | 0 | |||
(CBC Sec 504.2) | |||||
E. | Actual Floor Area: | ||||
Occupancy Type: | R-2 | ||||
Floor Level: | ASF | ||||
Basement | 0 | < 54,400 SF | |||
First Floor | 0 | < 54,400 SF | |||
Second Floor | 3,350 | < 54,400 SF | |||
Third Floor | 4460 | < 54,400 SF | |||
Fourth Floor | 1815 | < 54,400 SF | |||
Total Actual Floor Area | 9,625 | ||||
Occupancy Type: | M | ||||
Floor Level: | ASF | ||||
Basement | 0 | < 46,733 SF | |||
First Floor | 0 | < 46,733 SF | |||
Second Floor | 1000 | < 46,733 SF | |||
Third Floor | 0 | < 46,733 SF | |||
Fourth Floor | 0 | < 46,733 SF | |||
Total Actual Floor Area | 1000 | ||||
Occupancy Type: | U | ||||
Floor Level: | ASF | ||||
Basement | 0 | < 35,500 SF | |||
First Floor | 6000 | < 35,500 SF | |||
Second Floor | 0 | < 35,500 SF | |||
Third Floor | 0 | < 35,500 SF | |||
Fourth Floor | 0 | < 35,500 SF | |||
Total Actual Floor Area | 6000 |